UserManual_PCS500-K8031.pdf
(
523 KB
)
Pobierz
PC Scopes
PCS500
PCS100 / K8031
CHECK THE
Pc-Lab2000
T M
GETTING STARTED GUIDE
FOR SOFTWARE INSTALLATION
Reference Manual
PCS500 / PCS100 / K8031
VELLEMAN Instruments is a division of
VELLEMAN Components NV
Legen Heirweg 33
9890 Gavere
Belgium
Support & updates : http://www.Velleman.be
©Velleman
Instruments
HPCS500_GB- 2001– 1
2
PCS500 / PCS100 / K8031
FCC information for the USA
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Important
This equipment was tested for FCC compliance under conditions that include
the use of shielded test leads between it and the peripherals. It is important
that you use shielded cables and connectors to reduce the possibility of
causing Radio and Television interference.
Shielded probes, suitable for the PCS500 oscilloscope can be obtained
from the authorized Velleman dealer.
If the user modifies the PCS500 oscilloscope or its connections in any way,
and these modifications are not approved by Velleman, the FCC may withdraw
the user’s right to operate the equipment.
The following booklet prepared by the Federal Communications Commission
may be of help: “How to identify and Resolve Radio-TV Interference problems”.
This booklet is available from the US Government Printing Office, Washington,
DC20402 Stock No. 044-000-00345-4.
3
PCS500 / PCS100 / K8031
GENERAL
The PCS500 / PCS100 / K8031 are digital storage oscilloscopes, using a
computer and its monitor to display waveforms. All standard oscilloscope
functions are available in the Windows program supplied. Its operation is just
like a normal oscilloscope with the difference that most operations can be
done using the mouse. The markers for indicating voltage and frequency also
provide considerable ease of use and can be operated without difficulty using
the mouse. Apart from being used as an oscilloscope, the unit can also be
used as a spectrum analyzer and as a transient signal recorder, for recording
voltage variations or for comparing two voltages over a longer period (over
more than a year!). Connection is through the computer's parallel port; the
scopes are completely optically isolated from the computer port. Any waveform
displayed on the screen can be stored for later use in documents or for
comparison of waveforms. Together with the PCG10 function generator, a
powerful Bode plotter can be made. In the PCS500 the oscilloscope and
transient recorder have two completely separated channels.
PCS500 features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
4
Inputs: 2 channels, 1 external trigger input
Input impedance: 1 Mohm / 30pF
Frequency response
±
3dB: 0Hz to 50MHz
Maximum readout error: 2.5%
Low noise
Pre-trigger function
Maximum input voltage: 100V (AC + DC)
Input coupling: DC, AC and GND
Optically isolated from computer
Supply voltage: 9 - 10Vdc / 1000mA
Dimensions: 230x165x45mm (9x6.5x1.8”)
Weight: 490g (17oz)
PCS100 / K8031 features
1 channel input
Input impedance: 1 Mohm / 30pF
Frequency response ±3dB: 0 Hz to 12MHz
Maximum readout error: 2.5%
Slew rate 1div/10ns
Low noise
Maximum input voltage: 100V (AC + DC)
Input coupling: DC, AC, (GND only for PCS100)
Optically isolated from computer
Supply voltage: 9 - 10Vdc / 500mA
Dimensions: 230x165x45mm (9x6.5x1.8”)
Weight: 400g (14oz)
PCS500 / PCS100 / K8031
Minimum system requirements
•
•
•
•
•
•
•
•
IBM compatible PC
Windows 95, 98, ME, (Win2000 or NT possible)
SVGA display card (min. 800x600)
Mouse
Free printer port LPT1, LPT2 or LPT3
CD Rom player
Options
Insulated measurement probe x1 / x10:
PROBE60S
Soft carry case:
GIP
Technical data
PCS500 Oscilloscope
•
Time base: 20ns to 100ms per division
•
Trigger source: CH1, CH2, EXT or free run
•
Trigger level: adjustable in whole screen
•
Input sensitivity: 5mV (10mV for PCS100 / K8031) to 15V/division
•
Record length: 4096 samples / channel
•
Sampling frequency: Real time* 1.25 kHz to 50 MHz
•
Sampling frequency: Repetitive*: 1 GHz (Equivalent Sampling Rate)
PCS100 / K8031 Oscilloscopes
•
Time base: 0.1us to 100ms per division
•
Trigger source: CH1 or free run
•
Trigger level: adjustable per �½ division
•
Input sensitivity: 10mV to 3V per division
•
Record length: 4079 samples
•
Sampling frequency: Real time* 800Hz to 32MHz
PCS500 / PCS100 / K8031 general data
•
Trigger edge: rising or falling
•
Step markers for voltage, time and frequency
•
Interpolation: linear or smoothed
•
Vertical resolution: 8 bit
•
Auto setup function
•
True RMS readout (only AC component)
(*)
Real-time Sampling:
A sampling mode in which the picture is build by collecting as many samples
as it can as the signal occurs.
(*)
Equivalent Sampling rate:
A sampling mode in which the picture is builds using repetitive signals by
capturing information from each repetition.
5
Plik z chomika:
fred1144
Inne pliki z tego folderu:
PC_LAB2000_V1_19(1).zip
(2156 KB)
_SETUP(1).1
(1578 KB)
SETUP(1).INS
(65 KB)
README(1).TXT
(1 KB)
SETUP(1).EXE
(43 KB)
Inne foldery tego chomika:
# Audio
# IR
# PIC
150mW FM transmitter
15w FM-sändare
Zgłoś jeśli