sds1000dl_datasheet_en.pdf

(335 KB) Pobierz
DataSheet
SDS1000DL
Series Digital Oscilloscope
CHARACTERISTIC:
● The highest Single real-time
sampling rate can be up
to 500MHzsa/s; Equivalent sampling rate is up to 50GSa/s.
● Memory Depth: 32Kpts
● Trigger types: Edge, Pulse Width, Video, Slope, Alternative
● Unique Digital Filter function and Waveform
recorder function
● Support Pass/Fail function.
●Thirty two parameters Auto measure function.
● Save/recall types: Setups, Waveforms, CSV
file, Picture.
● Support Multilingual On-line
help system
● Waveform Intensity and Grid Brightness can be adjusted.
● Support twelve types Language
● Standard Configuration Port:
USB Host: Support USB flash driver save/recall function and update
firmware;
USB Device: Support PictBridge compatible printer and support PC
remote control;
RS232;
Pass/Fail Output.
Specifications
All specification applies to 10X probe and All the SDS1000DL Series Digital
Storage Oscilloscopes.
To verify that the oscilloscope meets specifications, the oscilloscope must first
meet the following conditions:
The oscilloscope must have been operating continuously for thirty minutes
within the specified operating temperature.
You must perform the Do Self Cal operation, accessible through the Utility
menu, if the operating temperature changes by more than 5° C.
The oscilloscope must be within the factory calibration interval
All specifications are guaranteed unless noted “typical.”
Inputs
Input Coupling
Input Impedance
Maximum
Input
voltage
Ch to Ch Isolation
(Both channels in
same V/div setting)
Probe Attenuator
Probe Attenuator
1X,5X,10X,50X,100X, 500X,1000X
Factors Set
Vertical System
Vertical Sensitivity
Channel
Voltage
Offset Range
Vertical Resolution
Channels
Analog
AC, DC, GND
1MΩ±2% || 16Pf±3Pf,
400V
(DC+AC
PK-PK,1MΩ input impedance,
X10),CAT I
>100:1 at 100MHz: (SDS1202DL)
>100:1 at 50MHz:(SDS1102DL)
>100:1 at 25MHz (SDS1052DL)
>100:1 at 10MHz (SDS1022DL)
1X,10X
2mV/div -10V/div(1-2-5 order)
2mV –200mV: ±1.6V
8 bit
2
200MHz(SDS1202DL)
206mV - 10V:
±40V
SIGLENT TECHNOLOGIES Co.,LTD
Add: 3/F, Building No.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, 518101, China
Tel: +86-755-3661 5186 Fax: +86-755-3359 1582 E-mail: sales@siglent.com Website: www.siglent.com
Bandwidth
Single-shot
Bandwidth
BW Flatness at BNC
input
100MHz(SDS1102DL)
50MHz(SDS1052DL)
25MHz(SDS1022DL)
200MHz(SDS1202DL)
100MHz(SDS1102DL)
50MHz(SDS1052DL)
25MHz(SDS1022DL)
DC -10% of rated BW: +/- 1dB
10% - 50% of rated BW: +/- 2dB
50% - 100% of rated BW: + 2dB/-3dB
Lower frequency limit
≤10Hz(at
input BNC)
(AC -3dB)
≤0.6 Div for average of 10 Pk-Pk
readings, Fixed
Noise: Pk-Pk for 3K
gain settings
≤0.7
Div for average of 10 Pk-Pk readings,
record
Variable gain settings
SFDR including
harmonics
>=35dB
(measured with FFT)
< ±
3.0%: 5mv/div to 10V/div in Fixed Gain
DC Gain Accuracy
Ranges
<±4.0%:
2mv/div Variable Gain Ranges
DC
Measurement
Accuracy:
±
[3%*
|reading|+|offset|
+1% *of |offset|
All Gain settings
+0.2div+2mv]
100mv/div
DC
Measurement
Accuracy:
±
[3%*
|reading|+|offset|
+1%* of |offset|
All Gain settings
+0.2div+100mv]
100mv/div
<1.8ns (SDS1202DL )
<3.5ns(SDS1102DL)
Rise time
<7.0ns (SDS1052DL )
<14ns (SDS1022DL )
Overshoot, Typical
<10% with probe or BNC input w/ 50 Ohm feed
(using 500ps pulse)
thru
<1ns: SDS1202DL
SDS1102DL
Ch to Ch Skew (both
<4ns: SDS1052DL
channels in same
<10ns: SDS1022DL
V/div setting)
(Equivalent to 2 minor divisions in smallest
t/div)
Math operation
+, -, *, /, FFT
SIGLENT TECHNOLOGIES Co.,LTD
Add: 3/F, Building No.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, 518101, China
Tel: +86-755-3661 5186 Fax: +86-755-3359 1582 E-mail: sales@siglent.com Website: www.siglent.com
FFT
Bandwidth limited
Horizontal System
Real
Time
Sampling Rate
Equivalent
Sampling Rate
Measure
Display
Modes
Timebase Accuracy
Horizontal
Range
Window mode: Hanning, Hamming, Blackman,
Rectangular
Sampling points: 1024
20MHz
±
40% (Note:
BW limited below
20MHz when using probe in x1)
Single
Channel:500MSa/s,Double
Channel:
250MSa/s( When timebase faster than 250ns/div)
50GSa/s (SDS1022DL:10GSa/s)
MAIN, WINDOW, WINDOW ZOOM, ROLL, X-Y
±100ppm
measured over 1ms interval
1/2.5/5/25nS/DIV - 50S/DIV (According to the
Scan
Bandwidth)
Scan: 100mS/DIV
�½�50S/DIV
(1-2.5-5 sequence)
Trigger System
Trigger Types
Trigger Source
Trigger Modes
Trigger Coupling
Trigger Level Range
Trigger Displacement
Trigger Level
Accuracy
(typical) applicable for
the signal of rising
and falling time
≥20ns
Edge, Pulse Width, Video, Slope, Alternative
CH1,CH2,EXT,EXT/5,AC Line
Auto, Normal, Single
AC, DC, LF rej, HF rej
CH1,CH2: ±6divisions from center of screen
EXT: ±1.2V
EXT/5: ±6V
Pre-trigger:(Memory depth/(2*sampling)),
Delay Trigger: 271.04DIV
Internal: ±(0.2 div×V/div)( within±4 divisions
from center of screen)
EXT:
±(6% of setting + 40 mV)
EXT/5: ±(6% of setting + 200 mV)
For fixed gain ranges
1 Divisions: DC-10MHz
1.5 Divisions: 10MHz - Max BW
EXT: 200mVpp DC-10MHz,
300mVpp 10MHz - Max BW
EXT/5: 1Vpp DC-10MHz,
1.5Vpp 10MHz - Max BW
Trigger Modes: (>,<,
=)positive
Pulse Width,
(>,
<, =)Negative
Pulse Width
Pulse Width Range: 20ns – 10s
Trigger Sensitivity
Pulse Width Trigger
SIGLENT TECHNOLOGIES Co.,LTD
Add: 3/F, Building No.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao'an District, Shenzhen, 518101, China
Tel: +86-755-3661 5186 Fax: +86-755-3359 1582 E-mail: sales@siglent.com Website: www.siglent.com