lifeplus_powertech_gb.pdf
(
579 KB
)
Pobierz
Smart Chargers
Hawker
Lifeplus
Powertech
Capability of of your battery fleet ... battery
Take control communication with the
Lifeplus
•
Powertech
Hawker, European leader in motive
power batteries, has pioneered High
Frequency charger technology. More
than 20 years expertise and a constant
study of the customer’s needs and
requirements has lead to Hawker’s new
range of smart chargers. With the abili-
ty to communicate with the battery we
can provide the optimal energy pack
needed for all motive power
applications.
The optimal solution
•
Hawker Lifeplus
This range is our premium brand
and at the leading edge of smart tech-
nology. These three phase, multivoltage
and multicapacity chargers are able to
communicate with the battery through
the Hawker easycontrol or easyplus,
the electronic device located on the
battery.
The chargers adapt automatically to:
•
Capacity of the battery
•
Voltage of the battery (Lifeplus)
•
Depth of discharge of the battery.
These factors plus high energy efficiency,
very high and constant power factor,
reduced overcharge factor and delayed
start of charge deliver significant energy
cost reductions.
Our HF charger Lifeplus and Powertech
ranges match all technologies of
lead-acid batteries (vented, gas
recombination: gel or AGM), especially
for Hawker battery ranges:
Hawker easycontrol or easyplus:
electronic device
With the Hawker easycontrol (Hawker
evolution batteries) or easyplus (flooded
batteries) located on the battery, the
Lifeplus and Powertech are capable of
communication with the battery and can
display the charge parameters for the
last 100 charges.
Automatic profile correction in relation
to temperature, when used with Hawker
easycontrol or easyplus, ensures correct
charge profile to safeguard charging
time and optimal service life.
•
Hawker Powertech
This range offers the ultimate
compromise in efficiency and
customer value. It is a single voltage
and multicapacity charger and it is
available in single phase and three
phase.
Benefits of HF technology
Optimal availability for use and long
service life can only be achieved from
motive power batteries when the
battery and the charger are perfectly
matched.
The HF technology permits:
•
compact wall-mounted
designs to save floor space
•
Hawker evolution (valve regulated
batteries with gel electrolyte)
•
Hawker perfect plus (vented batteries)
•
Hawker perfect plus with air mixing
•
Hawker wf200 plus (battery with
air mixing, very low maintenance)
•
significantly higher electrical
performances.
Thus the necessity for specific chargers
is replaced by the capability of multica-
pacity and multivoltage (with the
Lifeplus).
•
other low maintenance package
•
in Hawker Premier system
(low maintenance, heavy duty)
And offer high performances, reliability
and multipurpose use.
Smart and flexible state of the art technology
Main technical features
•
High power factor and efficiency
•
Optimal charge factor based on
depth of discharge
•
Temperature regulation
(gel, flooded with or without
electrolyte mixing)
•
Memory of last 100 charges
•
Menu:
•
Download of profiles on
PDA through RS232
•
•
•
•
•
•
•
Deferred start
Selection of equalization
Selection of charging profile
Temperature
Selection of cable length and section
Rest time of the battery
Electrically-operated valve (with control)
•
Optional extras
•
Red/green light
•
Automatic water topping up kit
•
Pneumatic air mixing pump kit
•
Download (profiles, memory) on PC,
or printer
Example of parameters stored by the charger
Nb T°C Cap
Batt.
Technology U
init
Ah+ U
final
Serial
Number
Gel
PbO
2.00 426
2.05 175
2.71
2.35
I
final
State
of charge
Init
29
40
Status
•
Charging status
(Incomplete Charge, Full Charge, Total
Incomplete Charges, Total Full Charges)
1
…
22
600 AC56123
520 AC12562
6
65
Complete
Disconnect
100 30
Front Panels
11
10
4
8
9
8
10
11
10
8
4
4
9
5
3
5
1
2
3
7
6
1
2
3
7
5
6
2
1
7
6
Three Phase
Clear, easily understood indications of
charge parameters on the LCD display
for these multivoltage, 3-phase chargers
Single Phase
Clear, easily understood indications of charge parameters on the LCD display for
these single voltage, single phase or 3-phase chargers
No.
1
Function
Red « Fault » light:
permanently lit, flashing or unlit
Yellow « Battery on charge » light:
permanently lit, flashing or unlit
Green « Battery available » light:
permanently lit, flashing or unlit
No.
4
5
Function
Digital display
Parameter/memory menu
Desulphation button
Start (position I) and Stop (positi-
on 0) switch
No.
8
9
10
Function
Battery technology
State of charge
Type of charger –
Available voltage
Software version
2
6
7
3
11
The optimal energy pack needed for all motive power applications
Complete solution
E-Maintenance
Data
Transfer
Chargers
Battery
electronics
Batteries
« Smart Pack »
Definition of application fields
1. Low duty
single shift with light operation and
discharge lower than 60 % C
5
,
electrolyte T °C about 30 °C
2. Normal duty
single shift with discharge up to
80 % C
5
, electrolyte T °C 30 °C
3. Heavy duty
•
single shift with discharges of
80 % C
5
and high discharging currents
•
opportunity charging to augment the
useable capacity
•
multi-shift operation with or without
battery changes
•
high ambient temperature
1. Low duty
2. Normal duty
3. Heavy duty
Hawker evolution
Hawker perfect plus
Hawker perfect plus
with electrolyte mixing
Hawker wf200 plus
Other low maintenance package
Hawker Premier system
Take control of your battery fleet
EnerSys battery fleet management
One of the challenges facing many com-
panies today is the effective management
of their fleet of motive power batteries.
Multi-shift manufacturing operations, lon-
ger retail trading hours and the demand
for faster logistics solutions are part of
everyday business life. Keeping your
materials handling equipment running,
often times 24 hours a day, to support
your business creates the need for bat-
tery changing. Selecting the "best bat-
tery" is vital to keep your truck fleet up-
time and productivity to a maximum.
EnerSys have a solution that makes
managing your battery fleet straight for-
ward and affordable. Communication
between the EnerSys HF chargers and
the pc is automatic and requires no data
input from your staff. Battery selection
by your truck operators is simple, it just
requires them to look at the screen.
BFM Software
The BFM program, wich is set up on a
pc, is an extremely easy to use “first in,
first out” system. The software can
manage up to 12 battery families and
500+ chargers. Each truck type or bat-
tery family is allocated a name and the
pc screen displays the relevant data:
“next battery”
“batteries available”
“batteries equalisation charging”
“defaults”
truck
type
batteries
available
best
battery
Look at the benefits ...
equalise
charging
PC screen
showing BFM
software with 6
battery families
•
maximises battery utilisation across
your fleet
•
avoids the need to dedicate batteries
to specific trucks
•
manages charging & battery rotation
•
reduces battery changing time
default
•
improve battery service life
•
integrates pc controlled automatic
equalisation charging
PowerNet
Building on the success of the BFM
system, EnerSys has developed the
PowerNet
software program which adds
some great new features for the effective
management of your charging room.
If you are dedicated to getting the optimum
performance and service life from your
battery fleet, having visibility and control
of your battery charging operation and
also controlling the amount of power
you use in the battery room then
Power-
Net
is what you have been waiting for!
Additional features
(When batteries are equipped with
easyplus devices)
•
Check status of all batteries
•
Check for over-discharging
•
Check for high operating temperatures
•
Identify potential faults (before break-
downs occur)
•
Identify which batteries require water
topping
PowerNet Software
Electricity power demand
Controlling the rate at which you use
electricity can have a dramatic impact on
how much you pay. Peaks in demand
above agreed thresholds generally mean
large premiums.
Fluctuating electrici-
ty consumption
without power
management
Balanced electricity
consumption using
PowerNet
•
"First in, first out" Battery Fleet
Management
•
Allocates "best battery" for each truck
type
•
Can manage 10 truck/battery families
•
Can manage 500+ chargers
•
Visibility of other fully charged batteries
•
Check status of all chargers
•
Visibilty of all charge cycles - number,
complete, incomplete & equalise
•
Remote access to data via internet
PowerNet
can be programmed to manage
the total power used in your battery
room by switching chargers on/off auto-
matically to maintain electricity consump-
tion within desired parameters.
Plik z chomika:
jas_pik
Inne pliki z tego folderu:
Curtis gen 2 1243ii (11B).pdf
(884 KB)
Curtis_1223.pdf
(965 KB)
1266 (11B).pdf
(2201 KB)
1254C.pdf
(614 KB)
series-motor-controller-1204.pdf
(637 KB)
Inne foldery tego chomika:
★ Instrukcja Urządzania Lasu ★
Administracja
Ampera Volt
Barańska A
budowa i takie tam
Zgłoś jeśli
naruszono regulamin